TM 11-6625-3081-23
7-37. TEMPERATURE SENSORS
7-37
INPUT CODE: AUGTEM (cont)
2. CORRECTIVE ACTION - SEGMENT 1 (cont)
(e) Check the following cable assemblies and repair as required:
2A2W1
2A2W7
2A2W19
2A2A7W3
If any cable was repaired, perform AUGTEM test. If AUGTEM test passes,
no further action required.
If AUGTEM test fails, repair is beyond
this level of maintenance.
Next higher level of maintenance required.
If no cables were repaired, repair is beyond this level of maintenance.
Next higher level of maintenance required.
If another segment displayed, proceed to that segment and continue
troubleshooting.
d. SEGMENT 2
1. VDT DISPLAY
ERROR IN HAND HELD TEMPERATURE PROBE HIGH READING. PERFORM THE FOLLOWING
REPLACE ACTIONS IN THE ORDER LISTED.
(REFERENCE TM 11-6625-3081-23 FOR
REPLACEMENT PROCEDURES.)
REF. DES.
PART NO.
NAME
1. 2A2W26
13081531
TEMP. PROBE ASSY.
2. 2A2A7A6A4
13082738
TEMP. MONITOR CCA
3. 2A2A13XX
AC4720
DIFF. INPUT CCA (J4)
4. 2A2A13
13081746
A/D CONVERTER
2 .
CORRECTIVE ACTION - SEGMENT 2
Corrective action same as segment 1. Refer to segment 1 for
troubleshooting.
7-192