TM 11-6625-3081-23
7-37. TEMPERATURE SENSORS
7-37
INPUT CODE: AUGTEM (cont)
2. CORRECTIVE ACTION - SEGMENT 4 (cont)
(c) Check the following cable assemblies and repair as required:
W1
1W4
2A3W1
2A3A1W16
If any cable was repaired, perform AUGTEM test. If AUGTEM test passes,
no further action required.
If AUGTEM test fails, repair is beyond
this level of maintenance.
Next higher level of maintenance required.
If no cables were repaired, repair is beyond this level of maintenance.
Next higher level of maintenance required.
If another segment displayed, proceed to that segment and continue
troubleshooting.
g. SEGMENT 5
1. VDT DISPLAY
ERROR ON DC SENSOR TEMPERATURE # TEMPERATURE READS #.##. PERFORM THE
FOLLOWING REPLACE ACTIONS IN THE ORDER LISTED. (REFERENCE
TM 11-6625-3081-23 FOR REPLACEMENT PROCEDURES.)
REF. DES.
PART NO.
NAME
1. 2A2A7A6A4
13082738
TEMP. MONITOR CCA
2. 2A2A13XX
AC 4720
DIFF. INPUT CCA (J4)
3. 2A2A13
13081746
A/D CONVERTER
4. 2A1A2W54
13081588-49
W54 SENSOR << OR >>
[2A1
13082800-59
DAYSIDE TEST BENCH].
2. CORRECTIVE ACTION - SEGMENT 5
(a) Remove Temperature Monitor CCA 2A2A7A6A4. Check contacts of mating
connectors and repair if required.
Install replacement 2A2A7A6A4 and
perform AUGTEM test.
If AUGTEM test passes, no further action
required.
If this segment displayed again, proceed to (b). If another
segment displayed, proceed to that segment and continue
troubleshooting.
(b) Remove Differential Input CCA 2A2A13XX (J4). Check contacts of mating
connectors and repair if required.
Install replacement 2A2A13XX and
perform AUGTEM test.
If AUGTEM test passes, no further action
required.
If this segment displayed again, proceed to (c). If another
segment displayed, proceed to that segment and continue
troubleshooting.
7-194