TM 11-6625-3081-237-37. TEMPERATURE SENSORS7-37INPUT CODE:AUGTEM (cont)a .DESCRIPTION (cont)The A source is programmed to 30°C and the A auxiliary temperature sensorchecked after a 200-second delay, for an indication of 27.5° to 32.5°C.If the indication is not within limits, a prompt is displayed.The B source is programmed for 35°C.The B controller temperature sensor ischecked after a 200-second delay, for an indication of 34.0° to 36.0°C.If the indication is not within limits, a prompt is displayed.The B source is programmed to 35°C.The B auxiliary temperature is checked,after a 200-second delay, for an indication of 32.5° to 37.5°C.If the indication is not within the limits, a prompt is displayed.The C source is programmed to 35°C and the C controller temperature sensorchecked, after a 200-second delay, for an indication of 34.0° to 36.0°C.If the indication is not within limits, a prompt is displayed.The C source is programmed to 35°C.The C auxiliary temperature sensor checked,after a 200-second delay, for an indication of 32.5° to 37.5°C.If the indication is not within limits, a prompt is displayed.7-189