TM 11-6625-3081-23
7-37. TEMPERATURE SENSORS
7-37
INPUT CODE: AUGTEM (cont)
2. CORRECTIVE ACTION - SEGMENT 6
(a)
(b)
(c)
(d)
(e)
(f)
Remove Control Unit Assembly 1A1.
Check contacts of mating connectors
and repair if required.
Install replacement 1A1 and perform AUGTEM
test.
(It is not mandatory to perform hand held temperature probe
portion of test.) If AUGTEM test passes, no further action required.
If this segment displayed again, proceed to (b). If another segment
displayed, proceed to that segment and continue troubleshooting.
Remove Temperature Monitor CCA 2A2A7A6A4.
Check contacts of mating
connectors and repair if required.
Install replacement 2A2A7A6A4 and
perform AUGTEM test.
(It is not mandatory to perform hand held
temperature probe portion of test.) If AUGTEM test passes, no further
action required.
If this segment displayed again, proceed to (c). If
another segment displayed, proceed to that segment and continue
troubleshooting.
Remove Differential Input CCA 2A2A13XX (J4). Check contacts of mating
connectors and repair if required.
Install replacement 2A2A13XX and
perform AUGTEM test.
(It is not mandatory to perform hand held
temperature probe portion of test.) If AUGTEM test passes, no further
action required.
If this segment displayed again, proceed to (d). If
another segment displayed, proceed to that segment and continue
troubleshooting.
Remove A/D Converter 2A2A13.
Check contacts of mating connectors and
repair if required.
Install replacement 2A2A13 and perform AUGTEM
test.
(It is not mandatory to perform hand held temperature probe
portion of test.) If AUGTEM test passes, no further action required.
If this segment displayed again, proceed to (e). If another segment
displayed, proceed to that segment and continue troubleshooting.
Remove Circuit and Heatsink 2A3A1A1A1XX (W24 SENSOR). Check contacts
of mating connectors and repair if required.
Install replacement
2A3A1A1A1XX and perform AUGTEM test.
(It is not mandatory to perform
hand held temperature probe portion of test.) If AUGTEM test passes,
no further action required.
If this segment displayed again, proceed
to (f).
If another segment displayed, proceed to that segment and
continue troubleshooting.
Remove Source A 2A3A1A1A1.
Check contacts of mating connectors and
repair if required.
Install replacement 2A3A1A1A1 and perform AUGTEM
test.
(It is not mandatory to perform hand held temperature probe
portion of test.) If AUGTEM test passes, no further action required.
If this segment displayed again, proceed to (g). If another segment
displayed, proceed to that segment and continue troubleshooting.
7-196