TM 11-6625-3081-237-36. PARALLEL BUS7-36INPUT CODE: PLLBUS (cont)2. CORRECTIVE ACTION - PLLBUS (cont)(f) Remove 5-volt Power Supply 1A4PS4.Check contacts of mating connectorsand repair if required.Install replacement 1A4PS4 and perform PLLBUStest.If PLLBUS test passes, no further action required.If PLLBUSfails, proceed to (g).(g) Remove Digital Computer Assembly 1A11. Check contacts of matingconnectors and repair if required.Install replacement 1A11 andperform PLLBUS test.If PLLBUS test passes, no further actionrequired.If PLLBUS fails, proceed to (h).(h) Check the following cable assemblies and repair as required:W7W141W21W71W92A2W5If any cable was repaired, perform PLLBUS test. If PLLBUS test passes,no further action required.If PLLBUS test fails and CALCST test hasbeen performed, repair is beyond this level of maintenance.Nexthigher level of maintenance required.If no cables were repaired and CALCST test has been performed, repairis beyond this level of maintenance.Next higher level of maintenancerequired.7-186