6-4. MAJOR TEST ADAPTER REPAIR (cont)
6-4
10. SILICONE RUBBER STRIP REPLACEMENT
REMOVAL
a.
To remove silicone rubber strip
(1) or (2) peel from bottom of
major test adapter.
b.
Scrape bonding area to remove
remaining particles.
TRICHLOROETHANE
FLAMMABLE, TOXIC, IRRITATING. CAN
CAUSE BREATHING PROBLEMS, EYE
DAMAGE.
AT 325°F, GIVES OFF PHOSGENE GAS,
WHICH CAN CAUSE DEATH OR SERIOUS
INJURY.
DONT:
USE NEAR FLAMES OR SPARKS,
LET IT GET ON SKIN, OR BREATHE
VAPORS.
DO:
USE IN WELL-VENTILATED AREA,
CLOSE CONTAINERS WHEN NOT USING.
WEAR ACID-TYPE SAFETY GOGGLES,
RUBBER GLOVES, AND RUBBER APRON.
IF IT CONTACTS SKIN OR EYES, WASH
AFFECTED AREAS WITH RUNNING WATER.
GET MEDICAL HELP AT ONCE.
IF YOU EXPERIENCE ANY BREATHING
PROBLEMS, GET TO FRESH AIR AT
ONCE.
c.
Clean bonding area using
cheesecloth pad moistened with
trichloroethane.
INSTALLATION
d.
e.
END OF TASK
6-10
Install silicone rubber strip (1)
using silicone adhesive.