TM 11-6625-3081-23
4-5
BLOWER ASSEMBLY 1A6 OR 1A12 REPAIR (cont)
4-5
NOTE
Ensure set screw is secured on flat
surface of motor shaft.
v.
Center fan blade (32) on motor
shaft and, using a ball driver
tool, tighten set screw (26).
NOTE
Blower motor can be installed with
blower exhaust ports facing down.
Make sure blower exhaust ports face
up after blower motor is installed.
w.
Position blower motor assembly
(10), with exhaust ports (33)
facing up, on bottom half of
blower housing (7).
x.
Set top cover (6) next to bottom
half of blower housing. Use lug
nuts (9) and splice three blower
motor wires (34) to three 115 vac
power input cable wires (8).
Remove tags.
y.
Install three wires (35) to
capacitor terminals (36), remove
tags, and position rubber grommet
(37) over terminals.
4-13