TM 11-6625-3081-234-5.BLOWER ASSEMBLY 1A6 0R 1A12 REPAIR (cont)4-5b.Use shorting probe and short outeach capacitor terminal toground.c.Loosen nut (5).d.Rotate capacitor bracket (6),loosen screw (7), and lift outcapacitor.e.Tag and remove three wires (8)from capacitor terminals.INSTALLATIONf.Install capacitor in reverseorder of removal.END OF TASKBLOWER MOTOR REPLACEMENTNOTEThis procedure is used to replace theblower motor contained in blowerassembly 1A6 (1) or 1A12 (1).REMOVALa.Refer to paragraph 1 above and dosteps a and b.b. Remove two retaining rings (4)from each grill (5) and lift outgrill.c.On rear of blower assembly (1),remove 11 screws (2) and eightscrews (3).4-9