TM 11-6625-3081-23
7-10. CAMERA TEST SPECIAL PURPOSE CABLE (EXTERNAL SOURCE)
7-10
INPUT CODE: DCEXSO (cont)
c .
DAY COLLIMATOR TARGET LAMP FAILURE
1. VDT DISPLAY
PERFORM THE FOLLOWING REPLACE ACTIONS IN THE ORDER LISTED. (REFERENCE
TM 11-6625-3081-23 FOR REPLACEMENT PROCEDURES.)
REF. DES.
PART NO.
NAME
1. XXXX
13081836
CAMERA TEST S.P. CABLE
2. 2A2A6XX
HP69331B
DIGITAL OUTPUT CCA (SLOT 408)
3. 2A2A7A4
13081572
RELAY ASSY.
4. 2A2A4A1
13083063
RELAY ASSY.
2. CORRECTIVE ACTION - DCEXSO
(a)
(b)
(c)
(d)
Remove Camera Test Special Purpose Cable W64. Check contacts of mating
connectors and repair if required. Install replacement cable and
perform DCEXSO test. If DCEXSO test passes, no further action
required.
If DCEXSO test fails, proceed to (b).
Remove Digital Output CCA 2A2A6XX (slot 408). Check contacts of mating
connectors and repair if required. Install replacement 2A2A6XX and
perform DCEXSO test. If DCEXSO test passes, no further action
required.
If DCEXSO test fails, proceed to (c).
Remove Relay Assembly 2A2A7A4. Check contacts of mating connectors and
repair if required. Install replacement 2A2A7A4 and perform DCEXSO
test.
If DCEXSO test passes, no further action required. If DCEXSO
test fails, proceed to (d).
Remove Relay Assembly 2A2A4A1. Check contacts of mating connectors and
repair if required. Install replacement 2A2A4A1 and perform DCEXSO
test. If DCEXSO test passes, no further action required.
If DCEXSO
test fails, proceed to (e).
7-49