TM 11-6625-3081-23
8 - 3.
ANALOG TO DIGITAL CONVERTER ASSEMBLY 2A2A13 (cont)
8 - 3
97.
98.
99.
100.
101.
102.
103.
104.
105.
106.
107.
108.
Install shorting plug on P3 of rf
cable assembly.
Press front panel ANALOG switch.
If necessary, adjust R301 (40)
until front panel DATA DISPLAY
indicates as close to O as pos-
sible.
(Upper limit is 4 and
lower limit is 177774.)
Remove shorting plug from P3 of rf
cable assembly.
Connect P3 of rf
cable assembly to unconnected con-
nector of 13081706-69 cable.
If necessary, adjust R305 (41)
until front panel DATA DISPLAY
indicates as close to 60000 as
possible. (Upper limit is 60004
and lower limit is 57774.)
Remove P3 of rf cable assembly
from 13081706-69 cable.
Set front panel digiswitches to
100270.
Install shorting plug on P4 of rf
cable assembly.
Press front panel ANALOG switch.
If necessary, adjust R401 (42)
until front panel DATA DISPLAY
indicates as close to O as possi-
ble. (Upper limit is 4 and lower
limit is 177774.)
Remove shorting plug from P4
of rf cable assembly. Connect
P4 of rf cable assembly to uncon-
nected connector of 13081706-69
cable.
If necessary, adjust R405 (43)
until front panel DATA DISPLAY
indicates as close to 60000 as
possible. (Upper limit is 60004
and lower limit is 57774.)
NOTE: POTENTIOMETER LOCATIONS MAY NOT BE
AS SHOWN. VERIFY LOCATIONS BY OBSERVING
STENCILING ON CCA.
E19LQ-635-26
Change 9
8-15