TM 11-6625-3081-238-3. ANALOG TO DIGITAL CONVERTER ASSEM8LY 2A2A13 (cont)8 - 373.74.75.76.77.78.If necessary, adjust R401 (31) untilfront panel DATA DISPLAY indicatesas close to 0 as possible.(Upperlimit is 4 and lower limit is177774.)Remove shorting plug from P4 of rfcable assembly. Connect P4 of rfcable assembly to unconnectedconnector of 13081706-69 cable.If necessary, adjust R405 (32) untilfront panel DATA DISPLAY indicatesas close to 60000 as possible.(Upper limit is 60004 and lowerlimit is 57774.)Disconnect P4 of rf cable assemblyfrom 13081706-69 cable.Press front panel POWER switch toremove power.CAUTIONThe A/D converter contains parts andassemblies sensitive to electro-static discharge (ESD). Use ESDprecautionary procedures (para 2-21)when touching, removing, orinserting CCAs.Remove rf cable assembly from CCA.Remove CCA extender from slot J5.Remove CCA from CCA extender.Install CCA in slot J5.8-12Change 8