TM 11-6625-3081-23
5-6. BASE ASSEMBLY REPAIR (cont)
5-6
(25)
(26)
(27)
Install two bolts (24) and
lockwashers (25). Tighten
bolts until just seated on
isolator.
Be sure piston
end of isolator remains flat
on mounting plate.
Install laminated shim (28)
as required to fill gap
under isolator at valve
end.
Torque bolts (24) to
54 ft-lb.
CAUTION
Do not use wrench on tubing nuts.
Finger tighten only.
(28)
(29)
(30)
(31)
Refer to diagram below and
attach two blue tubes (17)
to tee fitting (18) and
natural tube (19) to
opposite fitting (20).
Finger tighten only.
Attach blue tube (21) to
fitting (22) on isolator
(16).
Finger tighten
only.
Install piston plate (23)
on isolator (16).
Check that tubing is secured
by retaining clamps where
removed.
5-26