TM 11-6625-3081-23
5-6. BASE ASSEMBLY REPAIR (cont)
5-6
INSTALLATION
(18) Wrap teflon tape around
threads of fitting (22).
(19) Install fitting (22) into
replacement isolator (16).
WARNING
ISOPROPYL ALCOHOL
FLAMMABLE, TOXIC, IRRITATING. CAN
CAUSE BREATHING PROBLEMS, EYE
DAMAGE .
DONT:
USE NEAR FLAMES OR SPARKS,
LET IT GET IN EYES, OR BREATHE
VAPORS.
DO:
USE IN WELL-VENTILATED AREA,
CLOSE CONTAINERS WHEN NOT USING.
WEAR ACID-TYPE SAFETY GOGGLES.
IF IT CONTACTS EYES, WASH EYES
WITH RUNNING WATER. GET MEDICAL
HELP AT ONCE.
IF YOU EXPERIENCE ANY BREATHING
PROBLEMS, GET TO FRESH AIR AT
ONCE.
(20) Clean screws (26) and mating
holes in isolator (16) with
isopropyl alcohol.
(21) Apply sealing compound
primer to threads. Allow
to dry.
(22) Apply sealing compound to
screws (26).
(23) Install valve assembly (27)
with four screws (26).
Torque screws (26) to
14 ft-lb.
(24) Position isolator (16) on
mounting plate.
Aline with
mark made during removal.
5-25