TM 11-6625-3081-23
5-33. TEST ADAPTER PANEL ASSEMBLY 2A2A4 REPAIR
5-33
This task covers replacement of relays K1 through K12.
INITIAL SETUP
Equipment Condition
Material (appendix C)
Power removed (para 2-24.1)
Solder (Item 43)
Personnel Required
39B ATE Repairer
REMOVAL
1.
2.
3.
4.
NOTE
This procedure is used to replace any
of 12 relays K1 through K12.
Remove eight screws (1), lockwashers
(2), washers (3), and lower test
adapter panel assembly (4).
Remove four screws (5), lockwashers
(6), washers (7), and relay shield
(8).
Remove two front and loosen two rear
screws (9), washers (10), lockwashers
(11), and nuts (12) to gain access to
relay panel (13).
To remove any defective relay (14),
tag and unsolder leads, remove two-
screws (15), washers (16), lock-
washers (17), and nuts (18).
5-150
Change 2