TM 11-6625-3081-23
5-29. POWER SUPPLY ASSEMBLY 2A1A6 REPAIR
5-29
This task covers replacement of:
Para
Itern
Para
Itern
1.
High voltage power supply
3. Relays K1 or K2, connector J1,
assembly
2.
High voltage power supply
or terminal board Al
4.
Resistors R1 or R2, or
assembly CCA
capacitor C1
INITIAL SETUP
Personnel Required
39B ATE Repairer
Equipment Conditions
Power removed (para 2-24.1)
Cabinet rear panel removed
(para 2-41)
Material (appendix C)
FOLLOWUP
Solder (Item 43)
Cabinet rear panel installation
(para 2-41)
1. HIGH VOLTAGE POWER SUPPLY ASSEMBLY
REPLACEMENT
NOTE
For test and/or repair of high
voltage power supply assembly (except
CCA replacement) refer to TPS part
number 13082575.
REMOVAL
a.
Remove four screws (1.1),
washers (1.2), lockwashers (1.3),
and terminal board cover (1.4).
a.1.
Remove all wires from terminal
board TB1 (1).
Tag if necessary.
Replace one screw to secure
resistor R1 (2).
b.
Remove four screws (3), washers
(4), and electronic box assembly
cover (5).