TM 11-6625-3081-23
5-29. POWER SUPPLY ASSEMBLY 2A1A6 REPAIR (cont)
5-2Q
f. Loosen two screws (20) securing
connector 2A1W45P2 (21) to elec-
tronic box assembly connector J1
(22).
Separate connectors.
g.
Place electronic box assembly on
work bench and remove three
screws (23), washers (24), and
nuts (25) from relay K1 (26).
h.
Remove two screws (27), washers
(28), and nuts (29) from
relay K2 (30).
i.
Remove two nuts (31), lockwashers
(32), and posts (33) from connec-
tor J1 (22).
j.
Unsolder wires from relay K1 or
K2, connector J1, or terminal
board A1.
Tag wires, if
necessary.
INSTALLATION
k.
Install in reverse order of
removal.
END OF TASK
4. RESISTOR R1
REPLACEMENT
REMOVAL
OR R2, OR CAPACITOR C1
a.
Remove four screws (1),
washers (2), lockwashers (3),
and terminal board cover (4).
b.
Unsolder and remove resistor R1
(5), or R2 (6), or capacitor C1
(7) from solder lugs on terminal
board TB1 (8).
INSTALLATION
c.
Install in reverse order of
removal.
ENDOF TASK
5-130