5-15. OPTICAL SIGNAL ANALYZER PHOTOMULTIPLIER AND BRACKET ASSEMBLY
5-15
2A1A1A7 REPAIR (cont)
p.
Position photomultiplier and
bracket assembly (13) on mounting
plate assembly (11) and install
12 screws (14).
Note eight short
screws are located in recessed
area of plate assembly.
q.
Connect the following connectors:
A1P1 to W14J4 (7)
A1P2 to W14J5 (6)
A1P3 to W14J6 (5)
r.
Install shutter housing assembly
(10) with six screws (8) and
washers (9).
s.
Seal edges of shutter housing
assembly (10) with silicone
rubber.
t.
Remove lens paper covering from
exposed optics.
u.
Connect connector W14P1 to
connector A3J1 (4).
v.
Install baffle cover (3) with
16 screws (1) and washers (2).
,
END OF TASK