TM 11-6625-3081-23
5-15. OPTICAL SIGNAL ANALYZER PHOTOMULTIPLIER AND BRACKET ASSEMBLY
5-15
2A1A1A7 REPAIR (cont)
TRICHLOROETHANE
FLAMMABLE, TOXIC, IRRITATING. CAN
CAUSE BREATHING PROBLEMS, EYE
DAMAGE.
AT 325°F, GIVES OFF PHOSGENE GAS,
WHICH CAN CAUSE DEATH OR SERIOUS
INJURY.
DONT:
USE NEAR FLAMES OR SPARKS,
LET IT GET ON SKIN, OR BREATHE
VAPORS.
DO:
USE IN WELL-VENTILATED AREA,
CLOSE CONTAINERS WHEN NOT USING.
WEAR ACID-TYPE SAFETY GOGGLES,
RUBBER GLOVES, AND RUBBER APRON.
IF IT CONTACTS SKIN OR EYES, WASH
AFFECTED AREAS WITH RUNNING WATER.
GET MEDICAL HELP AT ONCE.
IF YOU EXPERIENCE ANY BREATHING
PROBLEMS, GET TO FRESH AIR AT
ONCE.
i.
Soften epoxy securing temperature
sensor (13) with trichloroethane,
and carefully remove temperature
sensor.
j.
Scrape and clean mounting area
with trichloroethane until no
residue appears on cheesecloth
pad.
5-81