TM 11-6625-3081-23
2-56. MULTIPROGRAMMER EXTENDER ASSEMBLY 2A2A11 REPLACEMENT (cont)
2-56
8.
9.
10
NOTE
If the multiprogrammer extender is to
be replaced, the ground lead will
have to be moved to the replacement
assembly.
If the same multiprogram-
mer extender is installed, use ground
lead disconnect and omit steps 8, 11,
and 13.
Remove screw (16), lockwasher (17),
washer (18), ground lead (19), and
washer (20).
Remove nut (21), lockwasher (22),
washer (23), and chain (24).
Close access door (5). depress slide
locks (25) and remove-multiprogrammer
extender assembly.
INSTALLATION
11. Prepare surfaces and hardware (16
thru 20) for application of zinc
chromate primer (para 2-19).
12. Install in reverse order of removal.
13. Apply thin coat of zinc chromate
primer over bonded area and hardware
(16 thru 20).
END OF TASK
2-294