TM 11-6625-3081-23
2-17. OPERATOR INSTRUCTION MESSAGES (cont)
2-17
When you press <PROCEED>, test program
loops back to step (3), compares the
current values with the ideal values
(step (4)), and waits for you to press
<YES> or <NO> to end left channel
adjustments (step (5)). If the
adjustments you made were not as close
as possible to the ideal values,
perform them again by pressing <YES>
as often as necessary.
When the best
possible adjustments are obtained,
press <NO> to exit.
POSITIONING READING ADJUSTMENT
(11) READING RIGHT CHANNEL POSITION
LEVELS
The current right channel position
values are determined.
(12)
IDEAL VAL
MEASURED
POS -4 POS -3 POS 0
UES:
0
32
128
VALUE:
POS 3
POS 4
223
255
The current right channel position
values are displayed on the VDT
directly under the ideal values.
(13) PRESS YES <F5> TO MAKE ADJUST-
MENTS TO THE RIGHT CHANNEL POSITIONING.
PRESS NO <F6> TO END ADJUSTMENTS TO
THE RIGHT CHANNEL.
(14) RIGHT CHANNEL POSITIONING
ADJUSTMENT ROUTINE.
1) TURN OFF CB5 (4) ON THE
ELECTRONICS STATION.
2) PULL OUT THE RIGHT PREAMP
AND REMOVE THE LEFT SIDE PANEL.
Change 9
2-142.15