TM 11-6625-3081-23
2-17. OPERATOR INSTRUCTION MESSAGES (cont)
2-17
(18) 1. DISCONNECT P13 OF CABLE
13083701 FROM PROGRAMMABLE DIGITIZER A2A1
CHANNEL A INPUT A ( 16).
2. DISCONNECT P14 OF CABLE 13083701 FROM
PROGRAMMABLE DIGITIZER A2A1 CHANNEL A
INPUT B (17).
3. DISCONNECT P16 0F CABLE 13083701 FROM
PROGRAMMABLE DIGITIZER A2A1 CHANNEL B
INPUT B (19). PRESS PROCEED WHEN
COMPLETE.
(19) 1. DISCONNECT P1 OF CABLE
13081706 FROM A1AkJ17 (15) AND DISCONNECT
P2 OF CABLE 13081706 FROM PROGRAMMABLE
DIGITIZER A2A1 CHANNEL B INPUT A (18).
2. DISCONNECT P8 OF CABLE 13083701 FROM
TEE CONNECTOR AT A1A1J17 (15).
3. DISCONNECT TEE CONNECTOR FROM A1A1J17
(15). PRESS PROCEED WHEN COMPLETE.
(20) 1. CONNECT P18 OF CABLE
13083701 TO PR0GRAMMABLE DIGITIZER A2A1
CHANNEL A INPUT B (17).
2. CONNECT P1 OF CABLE 13081706 TO
A2A7J21 (25) AND CONNECT P2 OF CABLE
13081706 TO PROGRAMMABLE DIGITIZER A2A1
CHANNEL B INPUT B (19).
(21) 1. DISCONNECT P18 OF CABLE
13083701 FROM PROGRAMMABLE DIGITIZER A2A1
CHANNEL A INPUT B (17). PRESS PROCEED
WHEN COMPLETE.
2. DISCONNECT P1 OF CABLE 13081706 FROM
A2A7J21 (25) AND DISCONNECT P2 OF CABLE
13081706 FROM PROGRAMMABLE DIGITIZER A2A1
CHANNEL B INPUT B (19). PRESS PROCEED
WHEN COMPLETE.
(22) 1. CONNECT P13 OF CABLE
13083701 TO PR0GRAMMABLE DIGITIZER A2A1
CHANNEL A INPUT A (16).
2. CONNECT CURRENT PROBE AMPLIFIER TYPE
134 TO PROGRAMMABLE DIGITIZER A2A1
CHANNEL A INPUT B (17).
3. SET CURRENT/DIV KN0B OF CURRENT PROBE
AMPLIFIER TO 1 A.
4. SET DEFLECTION FACTOR SWITCH OF
CURRENT PROBE AMPLIFIER TO P6021/O.4 MV.
5. CONNECT BNC CONNECTOR OF AC CURRENT
PROBE P6021 TO CURRENT PROBE AMPLIFIER.
PRESS PROCEED FOR ADDITIONAL
INSTRUCTI0NS.
2-142.10
Change 5