TM 11-6625-3081-23
2-14. MODULE DESCRIPTIONS (cont)
2-14
e. COMMON MODULES (cont)
Input Code
AUGTEM (cont)
Description
The B source is programmed to ambient, and the B controller
temperature sensor checked for an indication from -5.0° to
+lO.O°C of the recorded ambient temperature.
If the indication is not within limits, a prompt is displayed.
The C source is programmed for ambient and the C controller
temperature sensor checked for an indication from -5.0° to
+lO.O°C of the recorded ambient temperature.
If the indication is not within limits, a prompt is displayed.
The A source is programmed to 30°C. The A controller sensor is
checked, after a delay, for an indication of 29.0° to 31.0°C.
If the indication is not within limits, a prompt is displayed.
The A and C sources are programmed to -11° and +8°,
respectively, relative to ambient. The A auxiliary temperature
sensor is checked, after a delay, for an indication of -10° to
-12°, relative to ambient.
The C source is checked for
ambient -2° to ambient -4°.
If the indication is not within limits, a prompt is displayed.
The C source is programmed to 1° relative to A, and the A source
is programmed to 15° relative to ambient. The C auxiliary
temperature is checked, after a delay, for an indication of
32.5°C to 37.5°C.
If the indication is not within limits, a prompt is displayed.
The A source is programmed to +45° relative to ambient, and the
B source is programmed to 0° relative to ambient. The C
auxiliary temperature sensor and the B source are checked, after
a delay, for an indication of ambient plus 44°C to ambient plus
46°C.
Change 16