TM 11-6625-3081-23
2-14. MODULE DESCRIPTIONS (cont)
2-14
a.
ELECTRONIC STATION (cont)
Input Code
PSALIGN
Description
This module measures the output
power supplies at A/D converter
Ref. Des.
Output Voltage
1A4PS1
+28 vdc
1A4PS2
+15 vdc
1A4PS3
-15 vdc
1A4PS4
+5 vdc
voltages of the following fixed
assembly 2A2A13:
Voltage at A/D conv.
+7.703 to +7.255
+5.225 to +4.920
-5.073 to -4.920
+5.150 to +4.850
If a power supply output voltage is out of tolerance,
instructions are given to
accordingly.
This module also measures
power supply 1A3. If its
instructions are given to
accordingly.
adjust its output voltage
the output voltage of programmable
output voltage is out of tolerance,
adjust power supply controller 1A2
b.
DAYSIDE TEST BENCH 2A1
Input Code
DCALIGN
DCAMIR
2-66
Change 9
Description
This module positions the A and B mirrors for alinement. If it
cannot achieve proper positioning, it displays a prompt
informing the operator to run DCAMIR or DCBMIR, as appropriate,
for troubleshooting.
This module tests the ability of the A mirror to respond to com-
mands for both positions 1 and 2. The A mirror is programmed to
position 1 and the motor status checked.
A prompt is displayed at the completion of the test if motor
status is in error.
The A mirror is then programmed to position 2 and motor status
checked.
A prompt is displayed at the completion of the test if the motor
status is in error.