TM 11-6625-3081-23
5-16. OPTICAL SIGNAL ANALYZER POWER SUPPLY ASSEMBLY 2A1A1A6 REPAIR (cont)
5-16
b.
Remove three screws (4), lock-
washers (5), washers (6), clamp
(7), standoff (8), and nut (9),
securing relay K1 (10).
c.
Remove two screws (11), lockwash-
ers (12), washers (13), and
retaining strap (14).
d.
Remove four screws (15), lock-
washers (16), washers (17), and
remove power supply PS1 (18) with
relay, connectors, and wiring
from mounting bracket (19).
e. Clean and scrape silicone rubber
as required from power supply PS1
(18) to access solder terminals.
f.
Tag and remove the following
leads and remove power supply
PS1 (18).
5-86
Change 1