TM 11-6625-3081-23
5-1O. DAYSIDE TEST BENCH CABINET REPAIR (cont)
5-10
1. OPTICAL SIGNAL ANALYZER SLIDE
REPLACEMENT
R E M 0 V A L
NOTE
Use this procedure to remove either
left or right hand slide.
a. Loosen slide stop bolt (1), press
release catch (2), and slide
first two sections (3) off
stationary section (4).
b.
Remove 14 screws (5) securing
stationary section of slide to
cabinet.
Remove slide.
INSTALLATION
c.
Install in reverse order of
removal.
END OF TASK
2. OPTICAL SIGNAL ANALYZER CABLE
RETRACTOR REPLACEMENT
REMOVAL
a.
Remove three nuts (1), six wash-
ers (2), three screws (3), and
clamps (4) securing cable assem-
bly (5) to retractor (6).
b.
Remove four nuts (7), washers
(8), and screws (9) securing
retractor and standoff block (10)
to inner module. Remove retrac-
tor and standoff block.
INSTALLATION
c.
Install in reverse order of
removal.
END OF TASK
5-51