TM 11-6625-3081-23
5-6. BASE ASSEMBLY REPAIR (cont)
5-6
b.
If jacking of base is required to
access fittings on right side,
refer to 2a above and do steps 2
thru 9.
If access to fittings on
left side, refer to 2C above and
do steps 2 thru 9.
c.
Disconnect tube (1) from fitting
(2) on isolator.
d.
Remove defective fitting (3) from
end of tubing (1). If tubing is
damaged, cut off damaged portion.
If tubing is not long enough to
allow repair, replace tubing.
INSTALLATION
e.
Install replacement fitting (3)
over tubing (1).
CAUTION
Do not use wrench on tubing nuts.
Finger tighten only.
f.
Attach tube (1) with fitting (3)
to fitting (2) on isolator.
Finger tighten only.
9.
To lower base assembly from
jacks, refer to 2a above and do
steps 33 thru 39 for right side.
If left side of base was jacked,
refer to 2C above and do steps 32
thru 38.
h.
Refer to 1 above and install
protective skirts.
END OF TASK
5-41