TM 11-6625-3081-235-6.BASE ASSEMBLY REPAIR (cont)5-6INSTALLATION(9) Remove two screws (12) andvalve cover (13) fromreplacement valve (14) andinstall on defectivevalve (9).(10) Install valve cover (11)with adjusting arm onreplacement valve (14) withtwo screws (12).(11) Wrap teflon tape aroundthreads of fittings(3 and 5).(12) Install tee fittings (3 and5) into replacement valve(14).ISOPROPYL ALCOHOLFLAMMABLE, TOXIC, IRRITATING. CANCAUSE BREATHING PROBLEMS, EYEDAMAGE.DON’T:USE NEAR FLAMES OR SPARKS,LET IT GET IN EYES, OR BREATHEVAPORS.DO:USE IN WELL-VENTILATED AREA,CLOSE CONTAINERS WHEN NOT USING.WEAR ACID-TYPE SAFETY GOGGLES.IF IT CONTACTS EYES, WASH EYESWITH RUNNING WATER. GET MEDICALHELP AT ONCE.IF YOU EXPERIENCE ANY BREATHINGPROBLEMS, GET TO FRESH AIR ATONCE.(13) Clean screws (8) and matingholes in isolator (1) withisopropyl alcohol.(14) Apply sealing compoundprimer to threads, allowto dry.5-35