TM 11-6625-3081-23
2-17. OPERATOR INSTRUCTION MESSAGES (cont)
2-17
(79) ENTER SYNC PERIOD IN SECONDS:
(84) ENTER DELAY IN SECONDS
Enter desired sync period, then press
<RETURN>.
Test program programs the PPG to the
desired sync period.
3 - GATE PER1OD
(80) ENTER GATE PERIOD IN SECONDS:
Enter desired gate period, then press
<RETURN>.
Test program programs the PPG to the
desired gate period.
4 - ENABLE
(81) ENTER ENABLE CODE (O=OFF, 1=PPGS
ON, 2=LASER, 3=BOTH)
Enter desired enable code, then press
<RETURN>.
Test program enables or disables the
pulse generator, laser, or both.
5 - C MD
(82) ENTER CMD IN DECIMAL:
If you are familiar with the PPG
circuitry, enter 12-bit CMD word and
press <RETURN>.
Otherwise, just press
<RETURN>.
Test program programs the PPG with
the 12-bit CMD word if one was sent.
6 - PPG
(83) ENTER PPG NUMBER (1-5)
Enter desired number, then press
<RETURN>.
Enter delay, then press <RETURN>.
(85) ENTER DURATION IN SECONDS
Enter duration, then press <RETURN>.
Enter code, then press <RETURN>.
Enter gate delay, then press <RETURN>.
(88) ENTER GATE TIME IN SECONDS
Enter gate time, then press <RETURN>.
(89) ENTER GATE CODE
Enter gate code, then press <RETURN>.
(90) ARMGEN? [YES] OR [NO]
Press <YES> to arm the PPG output
counters, or <NO> if you do not wish to
arm them.
(91) ARMGATE? [YES] OR [NO]
Press <YES> to arm the PPG gate
counter or <NO> if you do not wish to arm
them.
Test program programs the program-
mable pulse generator according to the
data entered.
7 - ARM GEN
(92) PULSE, ARMEN
Test program arms the PPG output
counters.
8 - ARM GATE
Change 9
2-142.51