TM 11-6625-3081-23
2-17. OPERATOR INSTRUCTION MESSAGES (cont)
2-17
CONNECT P14 OF CABLE 13082730 T0
INTERFACE STATION A13A8J109 (12).
CONNECT P13 OF CABLE 13082730 TO
INTERFACE STATION A13A8J11O (13).
CONNECT P2 OF CABLE 13083693-19 TO MAJOR
TEST ADAPTER J3 (14).
CONNECT P1 OF CABLE 13083693-19 TO MAJOR
TEST ADAPTER J2 (15).
INSTALL PERSONALITY CARD SET IN MAJOR
TEST ADAPTER AS FOLLOWS:
1. OPEN DOOR, IF CLOSED, ON MAJOR TEST
ADAPTER.
2.
INSTALL P1 OF SIGNAL ROUTING
PERSONALITY CARD 13231525 IN ADAPTER
SLOT A7.
3.
INSTALL P1 OF PROGRAMMABLE RESISTOR
PERSONALITY CARD 13083641 IN ADAPTER
SLOT A6.
4.
INSTALL P1 OF SIGNAL CONDITIONING
PERSONALITY CARD 13082316 IN ADAPTER
SLOT A5.
5.
CLOSE AND SECURE DOOR ON MAJOR TEST
ADAPTER.
Refer to paragraph 2-69 for installation
procedure.
INSTALL UUT (PNVS NIGHT SENSOR ASSY) ON
NIGHTSIDE TEST BENCH 2A3 BY PERFORMING
THE PROCEDURES IN PARA 3-11 IN
TM 9-6625-476-30.
EXCEPTION
DO NOT REINSTALL MASK AND WINDOW
ASSEMBLY.
[SKIP SUBPARAGRAPH 2-11-C-(6)].
ENSURE THAT DUST COVERS AT P1 AND J1 OF
UUT ARE REMOVED.
DIRECT COOLING AIR DIRECTLY ONTO
COOLER/DEWAR A29/A30. REFER TO FIG. 3-30
[N TM 9-6625-476-30, IF NECESSARY, FOR
LOCATION OF COOLER/DEWAR.
2-142.24
Change 9