TM 11-6625-3081-23
7-6. A MIRROR
7 - 6
INPUT CODE:
DCAMIR (cont)
c .
A MIRROR SELF TEST FAILURE
1. VDT DISPLAY
PERFORM THE FOLLOWING REPLACE ACTIONS IN THE ORDER LISTED. (REFERENCE
TM 11-6625-3081-23 FOR REPLACEMENT PROCEDURES.)
REF. DES.
PART NO.
NAME
1. 2A2A6XX
HP69331B
DIGITAL OUTPUT CCA (SLOT 407)
2. 2A2A6XX
13083412
DIGITAL INPUT CCA (SLOT 401)
3. 2A2A7A6AI
13082741
STEPPER MOTOR CCA No. 1
4. 2A2A7A6A2
13082735
STEPPER MOTOR CCA No. 2
5. 2A2A7A6A3
13082732
STEPPER MOTOR CCA No. 3
6.
2A1
13082800-39
DAYSIDE TEST BENCH
2. CORRECTIVE ACTION - DCAMIR
(a) Remove Digital Output CCA 2A2A6XX.
Check contacts of mating connectors
and repair if required.
Install replacement 2A2A6XX and perform DCAMIR
test.
If DCAMIR test passes, no further action required.
If DCAMIR
test fails, proceed to (b).
(b) Remove Digital Input CCA 2A2A6XX.
Check contacts of mating connectors
and repair if required.
Install replacement 2A2A6XX and perform DCAMIR
test.
If DCAMIR test passes, no further action required.
If DCAMIR
test fails, proceed to (c).
(c) Remove Stepper Motor CCA No. 1 2A2A7A6A1. Check contacts of mating
connectors and repair if required.
Install replacement 2A2A7A6A1 and
perform DCAMIR test.
If DCAMIR test passes, no further action
required.
If DCAMIR test fails, proceed to (d).
(d) Remove Stepper Motor CCA NO. 2 2A2A7A6A2. Check contacts of mating
connectors and repair if required.
Install replacement 2A2A7A6A2 and
perform DCAMIR test.
If DCAMIR test passes, no further action
required.
If DCAMIR test fails, proceed to (e).
7-33