TM 11-6625-3081-23
5-37. PNEUMATIC CONTROL PANEL REPAIR (cont)
5-37
b. On bottom of filter, push valve
(3) up to bleed off air pressure.
c.
Tag and disconnect air supply
line (4) from gage (5).
d.
Remove two locknuts (6) securing
gage to panel. Remove gage.
e.
Remove
elbow (7) from gage.
INSTALLATION
f.
Remove teflon tape residue from
elbow threads and wrap with
teflon tape.
CAUTION
Do not use wrench on tubing nuts.
Finger tighten only.
g.
Install gage in reverse order of
removal.
END OF TASK
2. REGULATOR REPLACEMENT
REMOVAL
a.
Loosen two screws (1) and open
lower cabinet panel (2).
5-163