5-35. BLOWER ASSEMBLY 2A2A15 REPAIR
5-35
This task covers replacement of:
Para
Item
1. Motor
2.
Switch
INITIAL SETUP
Personnel Required
39BATE Repairer
Equipment Conditions
Power removed (para 2-24.1)
Blower removed (para 2-63)
FOLLOWUP
Blower installation (para 2-63)
1. MOTOR REPLACEMENT
REMOVAL
a.
b.
c.
5-156
Remove seven screws (1) and cover
(2) from blower assembly (3).
Tag and disconnect wire leads
from switch (4) and ac cord (5).
Remove four nuts (6), washers
(7), and motor and fan
assembly (8).
Change 2