TM 11-6625-3081-23
5-26.
INDIRECT VIEW DISPLAY 2A1A3 REPAIR (cont)
5-26
INSTALLATION
TRICHLOROETHANE
d.
e.
f.
g.
i.
END OF
FLAMMABLE, TOXIC, IRRITATING. CAN
CAUSE BREATHING PROBLEMS, EYE
DAMAGE.
AT 325°F, GIVES OFF PHOSGENE GAS,
WHICH CAN CAUSE DEATH OR SERIOUS
INJURY.
DONT:
USE NEAR FLAMES OR SPARKS,
LET IT GET ON SKIN, OR BREATHE
VAPORS.
DO:
USE IN WELL-VENTILATED AREA,
CLOSE CONTAINERS WHEN NOT USING.
WEAR ACID-TYPE SAFETY GOGGLES,
RUBBER GLOVES, AND RUBBER APRON.
IF IT CONTACTS SKIN OR EYES, WASH
AFFECTED AREAS WITH RUNNING WATER.
GET MEDICAL HELP AT ONCE.
IF YOU EXPERIENCE ANY BREATHING
PROBLEMS, GET TO FRESH AIR AT
ONCE.
Using a soft cloth moistened with
trichloroethane, clean terminal
block on fan assembly.
Scrape silicone residue from lugs
on fan cable leads and clean with
trichloroethane.
Position fan (5) into indirect
view display (3) and install
leads, as tagged, onto terminal
block (6) and install three
screws (7).
Position fan assembly (5) into
indirect view display (3) and
install four screws (4).
Position bottom cover (2) on
indirect view display (3) and
tighten 15 screws (1).
TASK