TM 11-6625-3081-23
2-35.
PMT CONTROLLER 1A7 REPLACEMENT (cont)
2-35
CAUTION
After panel screws are removed, PMT
controller is free of all holding
devices.
Support PMT controller
during removal of screws.
5.
Support PMT controller (10) and
remove four screws (11), lockwashers
(12), washers (13), and remove PMT
controller.
NOTE
If PMT controller is to be replaced,
ground lead will have to be moved to
the replacement assembly. If the
same PMT controller is to be
reinstalled, omit steps 6 through 11
and proceed to step 12.
6. Remove screw (14), lockwasher (15),
two washers (16), and ground lead
(6).
INSTALLATION
7.
Prepare surface and hardware (6, 14,
15, and 16) for application of zinc
chromate primer (para 2-19).
8.
Install ground lead (6) using screw
(14), lockwasher (15), and two
washers (16).
9.
Apply a thin coat of zinc chromate
primer over bonded area and hardware
(6, 14, 15, and 16).
10. Remove fuseholder cap (17) and fuse
(18), verify fuse rating and rein-
stall fuse and fuseholder cap.
11. Position 115/230 vac select switch
(19) to 115.
12. Install PMT controller in reverse
order of removal starting with
step 5.
END OF TASK
2-225