TM 11-6625-3081-23
2-17. OPERATOR INSTRUCTION MESSAGES (cont)
2-17
aj. OSACABLE MESSAGES (OSA ONLY)
(1) INSTALL MAJOR TEST ADAPTER
13083633-19 IN AH-64A TEST SET/PIU
CONNECTOR A1A9J1 AND CLOSE LOCKING LEVER.
VERIFY THAT NO PERSONALITY CARDS INSERTED
IN MAJOR TEST ADAPTER CONNECTORS A5 (1),
A6 (2), A7 (3), A8 (4), A9 (5). PRESS
PROCEED WHEN COMPLETE.
(2) INSTALL CABLE ASSEMBLY 13082730
AS FOLLOWS:
P1 TO MAJOR TEST ADAPTER 13083633-J4 (6)
P3 TO AN/USM-410 DIU A1A4-J26
P4 TO AN/USM-410 D1UA1A4-J32
P5 TO AN/USM-410 DIU A1A4-J1
P6 TO AN/USM-410 DIU A1A4-J2
P7 TO AN/USM-410 DIU A1A4-J9
P9 TO AN/USM-410 DIU A1A4-J29
P1O TO AN/USM-410 DIU A1A4-J30
P11 TO AN/USM-410 DIU A1A4-J34
P12 TO AN/USM-410 DIU A1A4-J36
P13 TO AN/USM-410 INTERFACE STATION
A2A13A8J109
P14 TO AN/USM-410 INTERFACE STATION
A2A13A8J11O
PRESS PROCEED WHEN COMPLETE
(3) OPEN DOOR, IF CLOSED, ON MAJOR
TEST ADAPTER. INSTALL P2 OF SIGNAL
ROUTING PERSONALITY CARD 13082365 IN
ADAPTER CONNECTOR A7 (3). INSTALL P2 OF
SPARE PERSONALITY CARD 13082411 IN
ADAPTER CONNECTOR A9 (5). CLOSE AND
SECURE DOOR ON MAJOR TEST ADAPTER. PRESS
PROCEED WHEN COMPLETE.
2-140.2
Change 4