2-17. OPERATOR INSTRUCTION MESSAGES (cont)
2-17
ae. IVDST MESSAGES (OSA ONLY)
(1) INSTALL MAJOR TEST ADAPTER
13083633-19 IN PIU STATION A9J1 AND CLOSE
LOCKING LEVER.
Refer to paragraph 2-65 for installation.
VERIFY THAT NO PERSONALITY CARDS ARE
INSERTED IN MAJOR TEST ADAPTER CONNECTORS
A5 (1), A6 (2), A7 (3), A8 (4), A9 (5).
PRESS PROCEED WHEN COMPLETE.
(2) INSTALL CABLE ASSEMBLY 13082730
AS FOLLOWS:
P1 TO MAJOR TEST ADAPTER 13083633-J4 (6).
P3 T0 AN/USM-410 DIU A1A4-J26
P4 T0 AN/USM-410 DIU A1A4-J32
P5 T0 AN/USM-410 DIU A1A4-J1
P6 TO AN/USM-410 DIU A1A4-J2
P9 TO AN/USM-410 DIU A1A4-J29
P1O TO AN/USM-410 DIU AIA4-J30
P11 TO AN/USM-410 DIU A1A4-J34
P12 TO AN/USM-410 DIU A1A4-J36
P13 TO AN/USM-410 YIU A8-J11O
P14 T0 AN/USM-410 YIU A8-J109
PRESS PROCEED WHEN COMPLETE.
(3) INSTALL PERSONALITY CARD SET IN
MAJOR TEST ADAPTER AS FOLLOWS:
OPEN DOOR, IF CLOSED, ON MAJOR TEST
ADAPTER.
INSTALL P1 OF PROGRAMMABLE RESISTOR CARD
13083641 IN MAJOR TEST ADAPTER CONNECTOR
A6 (2).
INSTALL P2 OF SIGNAL ROUTING PERSONALITY
CARD 13082365 IN MAJOR TEST ADAPTER
CONNECTOR A7 (3).
INSTALL P2 OF SPARE PERSONALITY CARD
13082411 IN MAJOR TEST ADAPTER CONNECTOR
A9 (5).
CLOSE AND SECURE DOOR ON MAJOR TEST
ADAPTER.
PRESS PROCEED WHEN COMPLETE.
2-124