TM 11-6625-3081-23
2-64. NIGHTSIDE TEST BENCH CABINET REPAIR (cont)
2-64
g.
h.
i.
On front of nightside test bench,
open access door (22).
On underside of nightside test
bench, loosen four screws (23),
rotate four retainers (24), and
remove bench top (25).
Remove six long screws (26), two
short screws (27), and washers
(28) securing front panel (29) to
cabinet.
Remove front panel.
2-313