TM 11-6625-3081-23
7-24. OPTICAL - HOD AND IVD ALIGNMENT ASSEMBLY
7-24
INPUT CODE: FIXTST (cont)
2 .
CORRECTIVE ACTION
- SEGMENT 5 (cont)
(b) Check the following test cables and test connectors and repair as
required:
Test cables - 13081706, 13082730, 13083702
Test connectors - 13083962-419, 13083962-429, 13083962-439, and
13083962-449
If any cable or connector was repaired, perform FIXTST test. If
FIXTST test passes, no further action required.
If FIXTST test fails
and CALCST, PLLBUS, MTRXSW, ADST, DIGITST, FPSST, and PPSST tests have
been performed, repair is beyond this level of maintenance. Next
higher level of maintenance required.
If no cables or connectors were repaired and CALCST, PLLBUS, MTRXSW,
ADST, DIGITST, FPSST, and PPSST tests have been performed, repair is
beyond this level of maintenance.
Next higher level of maintenance
required.
If another segment displayed, proceed to that segment and continue
troubleshooting.
7-120