TM 11-6625-3081-23
2-17.
OPERATOR INSTRUCTION MESSAGES (cont)
2-17
ao. 0SGALIGN MESSAGES
(1) THE FOLLOWING EQUIPMENT IS
REQUIRED TO PERFORM THE OSG ALIGNMENTS:
- DIU CABLE ASSEMBLY, P/N 13082730
- SPECTRA SPOTMETER
- RADIOMETER TEST CABLE, P/N TE782073
- SPOTMETER FIXTURE, P/N TE782036
- POTENTIOMETER ADJUSTMENT TOOL
(2) A.
CONNECT CABLE ASSEMBLY
1308273O-P1O TO AN/USM 410 DIU A1A4-J30
(1).
(3) B. CONNECT CABLE ASSEMBLY
13082730-P2 TO TEST ADAPTER PANEL
ASSEMBLY 2A2A4J6 (2).
2-142.30
Change 9