TM 11-6625-3081-23
2-8. TEST CONSOLE TEST BENCH 2A2 CONTROLS AND INDICATORS (cont)
2-8
PROGRAMMABLE DIGITIZER 2A2A1 (cont)
Key
18
19
20
21
22
Control or Indicator
COPY Switch
PROGRAM CHANNEL B
Switch
PROGRAM CHANNEL A
Switch
ARM A Switch
ARM B Switch
Function
Copies settings from selected time base to other time
base.
Example:
Selects B
ger
Time base A is selected (CHANNEL A button lit).
Pressing COPY button will copy all settings
from time base A to time base B.
channel to be programmed by time base and trig-
function entries.
Displays settings of channel B on front panel.
Selects A channel to be programmed by time base and
trigger function entries.
Displays settings for channel A on front panel.
Arms the A time base.
If changes were made to A time
base settings since last arm operation, validity of
settings is first verified.
If errors are found during
verification, a warning message is displayed in RECORD
LENGTH indicators.
When ARM operation is complete, time
base becomes triggerable.
Arms the B time base.
If changes were made to B time
base settings since last arm operation, validity of
settings is first verified.
If errors are found during
verification, a warning message is displayed in SAMPLES
indicators.
When ARM operation is complete, time base
becomes triggerable.
2-21