TM 11-6625-3081-23
7-34. SHUTTER ASSEMBLY 2A3A1A2
7-34
INPUT CODE:
FIRCSST (cont)
2. CORRECTIVE ACTION - FIRCSST (cont)
NOTE
Cable assemblies 2A3A1A2W7 and 2A3A1A2W8, and shutter
assembly 2A3A1A2 are depot level repair only. Removal and
installation of these items are not authorized at AVIM.
(e) Check the following cable assemblies and repair as required:
W8
W12
2A2W8
2A2W9
2A2W13
2A3W3
2A3W4
If any cable was repaired, perform FIRCSST test. If FIRCSST test
passes, no further action required.
If FIRCSST test fails and CALCST,
PLLBUS, MTRXSW, ADST DIGITST, FPSST, and PPSST tests have been
performed, repair is beyond this level of maintenance. Next higher
level of maintenance required.
If no cables were repaired and CALCST, PLLBUS, MTRXSW, ADST, DIGITST,
FPSST, and PPSST tests have been performed, repair is beyond this level
of maintenance.
Next higher level of maintenance required.
7-178