TM 11-6625-3081-23
2-40.
DIGITAL COMPUTER ASSEMBLY 1A11 REPAIR (cont)
2-40
c.
If CCA has connector (3, 4, 5, 6,
or 7) installed, disconnect
connector.
d.
If removing CCA A1 or A2, remove
frontplane (8).
e.
If removing CCA A5 or A6, remove
frontplane (9).
CAUTION
This equipment contains parts and
assemblies sensitive to damage by
electrostatic discharge (ESD). Use
ESD precautionary procedures when
touching, removing, or inserting
circuit card assemblies.
f.
Comply with ESD procedures for
CCAs (para 2-21).
g.
On CCA, loosen screw and move
retainer clear of CCA; release
two thumb levers and remove CCA
by pulling CCA straight out.
INSTALLATION
CAUTION
This equipment contains parts and
assemblies sensitive to damage by
electrostatic discharge (ESD). Use
ESD precautionary procedures when
touching, removing, or inserting
circuit card assemblies.
h.
Comply with ESD procedures for
CCAs (para 2-21).
Change 6
2-245