TM 11-6625-3081-23
2-34. BLOWER ASSEMBLY 1A6 OR 1A12 REPLACEMENT (cont)
2-34
INSTALLATION
12. On replacement blower assembly,
remove 11 screws (16) and separate
blower assembly housing (17).
13. Prepare surface and hardware (18
thru 22) for application of zinc
chromate primer (para 2-19).
14. Install ground lead (22) using
washers (20), lockwasher (19), screw
(18), and nut (21).
15. Apply a thin coat of zinc chromate
primer over bonded area and hardware
(18 thru 22).
16. Close up blower assembly housing (17)
using 11 screws (16).
17. Inspect filter for defects and clean-
ness (para 2-22).
18. Install blower assembly in reverse
order of removal beginning with
step 8.
END OF TASK
2-223