TM 11-6625-3081-23
2-34. BLOWER ASSEMBLY 1A6 OR 1A12 REPLACEMENT (cont)
2-34
6.
Push dc power supply assembly into
cabinet.
7.
On front of blower assembly, loosen
two nuts (10), and remove grill (11)
and filter (12).
8.
Remove four screws (13), lockwashers
(14), and washers (15), and remove
blower assembly.
NOTE
If blower assembly is to be replaced,
ground lead will have to be moved to
the replacement assembly. If the
same blower assembly is to be
reinstalled, omit steps 9 through 16
and proceed to step 17.
9. On blower assembly, remove 11 screws
(16) and separate blower assembly
housing (17).
10. Remove screw (18), lockwasher (19),
three washers (20), nut (21), and
ground lead (22).
11. Close up blower assembly housing (17)
using 11 screws (16).