TM 11-6625-3081-23
2-17. OPERATOR INSTRUCTION MESSAGES (cont)
2-17
ak. VIDEOST MESSAGES
(1) PLACE THE PORTABLE MONITOR (1)
ON THE INTERFACE STATION A13 TABLETOP
WITH THE CRT FACING THE OPERATOR.
PLUG THE PORTABLE MONITOR POWER CORD INTO
THE TEST ADAPTER PANEL ASSEMBLY A2A4J3
(2).
PRESS PROCEED WHEN COMPLETE.
(2) 1. CONNECT P7 0F CABLE
A3003942 TO INTERFACE STATION A13A8J106.
2. CONNECT CONNECTOR ADAPTER 901-167 TO
P3 0F SELF-TEST CABLE A3003942.
3. CONNECT P1 OF CABLE 13081706-69 TO
CONNECTOR ADAPTER 901-167 AND CONNECT P2
OF CABLE 13081706-69 TO EXT SYNC
CONNECTOR (3) ON REAR PANEL OF PORTABLE
MONITOR.
SET SYNC SWITCH (4) ON REAR OF
MONITOR TO EXT.
2-142
Change 4
4. CONNECT SECOND CONNECTOR ADAPTER
901-167 TO P6 0F SELF-TEST CABLE
A3003942.
5. CONNECT P1 OF SECOND CABLE
13081706-69 TO THE CONNECTOR ADAPTER AND
CONNECTOR P2 TO THE 'VIDEO-IN' CONNECTOR
(5) ON REAR PANEL OF THE PORTABLE
MONITOR.
SET VIDEO SWITCH (6) ON REAR OF
MONITOR TO 75 OHMS. PRESS PROCEED WHEN
COMPLETE.